Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
International Journal of Laboratory Medicine ; (12): 2357-2359, 2017.
Article in Chinese | WPRIM | ID: wpr-613067

ABSTRACT

Objective To compare the immunostaining of human epidermal growth factor receptor-2(HER-2) among three different clones,and to compare with the results of fluorescence in situ hybridization(FISH) detection,to provide evidences for pathological department to select appropriate antibodies.Methods 268 cases of invasive breast cancer were examined by immunohistochemistry using antibodies for HER-2 of 3 different clones.The results were compared with those done by FISH.Results Immunostaining using antibody clone SP3 showed 3+ reactions in 66 cases;Immunostaining using antibody clone EP3 showed 3+ reactions in 53 cases,while using polyclonal HER-2 antibody,80 cases showed 3+ reactions.There was statistical significance between those groups using different clones(P<0.05).Consistent with the FISH results,the Kappa values are 0.76,0.67,and 0.56,respectively.Conclusion It suggests detection of HER-2 using immunohistochemistry should prioritize selecting monoclonal antibodies,especially clone SP3.

2.
Chongqing Medicine ; (36): 4396-4398,4402, 2015.
Article in Chinese | WPRIM | ID: wpr-602639

ABSTRACT

Objective To investigate oxygen nebulizer usage among inpatients in an upper first‐class hospital so that this de‐vice can be used by medical personnel and patients properly .Methods Totally 409 patients were investigated about the usage of the device from May 12th to 30th 2014 ,whose outcomes were analyzed by Excel2007 software .Results The total liquid volume of in‐halation on prescription was much larger than the favorable one ,ranging from 4 to 6 mL .And the Oxygen flow ,ranging from 2 .5 to 3 .5 L/min ,was much lower than the normal flow (ranging from 6 to 8 L/min) .In addition ,all patients failed to breathe normally with occasional deep breaths and failed to gargle timely after corticosteroid inhalation .Only 3% patients cleaned their faces after corticosteroid inhalation ,43 .5% patients sit in an upright position ,44 .0% patients kept the nebulizer vertical during treatment .The accuracy rates of mouthpiece position ,the right time to stop nebulizer therapy ,rinsing the nebulizer with sterile or distilled water and allowing to air dry were 95 .1% ,99 .2% ,and 99 .3% ,respectively .Conclusion There are many common patient use nebulizer incorrectlly in the upper first‐class hospital ,and education and guidance by medical personnel should be strengthened .

SELECTION OF CITATIONS
SEARCH DETAIL